O2 Concentrator - 10L
10-Liter Oxygen Concentrator is a high-output stationary home oxygen device capable of continuously extracting and delivering up to 10 liters per minute of concentrated oxygen from room air.
Available Variants
O2 Concentrator - 10L (5 LPM, Continuous)
O2 Concentrator - 10L (5 LPM, PRN)
O2 Concentrator - 10L (6 LPM, Continuous)
O2 Concentrator - 10L (6 LPM, PRN)
O2 Concentrator - 10L (7 LPM, Continuous)
O2 Concentrator - 10L (7 LPM, PRN)
O2 Concentrator - 10L (8 LPM, Continuous)
O2 Concentrator - 10L (8 LPM, PRN)
O2 Concentrator - 10L (9LPM, Continuous)
O2 Concentrator - 10L (9LPM, PRN)
O2 Concentrator - 10L (10LPM, Continuous)
O2 Concentrator - 10L (10LPM, PRN)
O2 Concentrator - 10L (>10LPM, Continuous)
O2 Concentrator - 10L (>10LPM, PRN)
Operating Instructions
Emergency telephone number is on your equipment. (618)234-0202
Please follow instructions given by the equipment technician. Please follow your doctor's orders. Oxygen is a drug and must be ordered by a doctor.
Use your oxygen at _______LPM (Liters per minute).
Frequency _________________________________.
Set-up
- Plug oxygen concentrator into wall outlet.
- Connect tubing adapter to oxygen outlet port. Optional - Humidifier jar may be used for high liter flows, or if ordered by physician. Distilled water is to be used in the humidifier jar.
- Connect oxygen tubing to the outlet port.
- Connect oxygen cannula to oxygen tubing.
- Turn oxygen concentrator on.
- Set prescribed liter flow.
- Demonstrate how to place cannula on patient.
- Patient/Caregiver demonstrates each step and has a solid understanding.
- Review how to order supplies. When to order. Where to call.
Cleaning
- External filters should be rinsed free of dust each week. Dry thoroughly.
- Humidifier jar should be washed each day in soapy detergent water. Rinse well. Soak for 30 minutes in a mixture of (1 part white vinegar and 4 parts water). Rinse well. Fill with distilled water. Humidifier jar should be replaced each month.
- Nasal cannula can be wiped off with soapy water. Wipe soap off with a damp cloth. Cannula should be changed every 2 weeks.
- Exterior of oxygen concentrator should be dry dusted each week.
Safety
- Oxygen must be at least 5 feet from an open flame.
- Do not smoke near the oxygen.
- Do not use oil based products on the patient's face. No vaseline.
- Do not move oxygen concentrator to another location.
- Maintain at least 12-18 inches of free air space around unit. Do not push up against a wall or a curtain.
- Post "NO SMOKING" signs.
OxyCare Medical Supply Co. 2725 South Belt West, Belleville IL 62226